Min Time 060:00 Then OFF, Fallback OFF The sooner you know theres a problem, the sooner you can work on fixing it. Defer 001:00 Then ON, Set OFF You are limited to 12 characters, and the name must be unique within your list of outputs, inputs, and module names. If you do not see the 5 new tiles on the Dashboard, they might be found in the unused tile area, which you can open by clicking the button that looks like a padlock in the top right of the Apex Fusion dashboard; you can then drag the desired tiles out onto the dashboard. JavaScript is disabled. Once triggered, the output is forced into manual OFF mode and the programming will no longer operate until you manually move the slider back to the AUTO position. If ATK_LO OPEN Then ON Id like to thank Zombie and RussM, two of the most frequent contributors on the Neptune Community Forums. These outputs are physical, tangible electrical outlets that have power cords plugged in. Neptune Apex PMUP V2 Stand with Optical Eye Holder - 3D Printed - Reef Safe . A float valve acts as another failsafe in case both optical sensors fail, and lastly there is a built-in timer that acts as a final failsafe to turn off the pump if it runs too long. Since moonrise varies day to day, sometimes its visible at night, but sometimes its during the day. Dimension Head Unit - 4.75" L x 5.25" H x 3.25" W Energy Bar 832 - 10" L x 6.5" H x 2.25" W A3 Apex Bundle Includes: 1x A3 Apex Base Unit 1x EB832 Energy Bar 832 1x Temperature Probe 1x pH Probe 1x MOS Magnetic Optical Sensor I know it will then make the physical float valve lower than the hi sensor, but Im sick of 30-40 alarm a day (the hi ATK for some reason sends out about four alarm messages at a time). ZGRmMzgyZDE5Y2I4Zjc3OGVkNGY4OWQzYjA0Yzc0Mjg2MjBlMDkwOTNmMjVi In order to calculate the energy costs, you need to enter your electricity rate from your utility bill: Now Fusion can report your estimated daily and monthly energy costs in the Power Log: The log can also show individual outlet usage in the graph if you click the Compare dropdown at the upper right: Most Apex alerts are configured as lines of programming under the Email_Alarm output. This could include water changes, cleaning out the sump, making plumbing repairs, or anything where you might not want the heater to come on since it may not be submerged in water. Sometimes you might want an output to turn on only if two or more conditions are true. ZTQ3ZTZkN2VmZTkyMzU2YTRiYmRhNjAwOTNhYTJkMGRmM2U3NGIxNWRiYmVh Announcing the BRAND NEW Orphek Atlantik iCon! If Error ATK_PMUP Then ON Also confirm the PMUP is fully submerged in the ATO reservoir, and that the tubing is not kinked or blocked. Here is a reference guide for all of the Neptune Apex programming commands. If Float1 Open Then ON Defer 000:10 Then OFF Thank you for writing these tutorials. It's so thoughtful of you to do this, I plan on getting one soon so your posts will be extremely helpful. Sent from my BLU R1 HD using Tapatalk, Sundays topic - Lunar Schedule and Lighting Profiles. Earn 3,360 Reward Points, Earn 479 Reward Points You can test a leak detection probe by placing the probe on a wet paper towel. Just remember, the time will vary each day, and some nights you will not see any moon lights on because the moon is not actually visible in the sky. This assumes that our ATO pump should never need to run for more that 3 minutes straight under normal evaporation conditions. LeakL, LeakR (for probes positioned on the left and right inside your tank stand or beside the tank), LDreef, LDfrag (for probes positioned near or under two different tanks, such as a reef tank and a frag tank. Click the padlock icon to access the Unused Tiles screen. The simplest method for probes or certain Inputs is to use the built-in alarm feature on its configuration page. MWI1NzI3NzJiZDg5N2Q1MThhZGM2ZjQxNjM0NjQ0YmU2MDE4NDZkMjczM2M2 After testing, remember to add that line back to the programming since its there as a safeguard. If it doesn't move any water, verify the 24v power adapter is firmly plugged in to the FMM and that it has power. So weird! I also have the klir but due to sump design the optic sensor will not work. Starting this Monday, I'll be posting one tutorial per day on the following topics: After this series, if there are any specific topics you'd like covered, let me know. It only shows what the sensor or probe is measuring: Outputs can be manually turned ON or OFF, or can be set to AUTO. Using our ATO pump example from above, here we add the When command. The output programming is only active when the output is set to AUTO, and the state of the output will be displayed above the tile: This brief introduction only touches on the main points of Apex programming. For testing purposes, you can lower the Defer timers, or delete them. Defer 000:15 Then OFF, Set OFF If Tmp > 78.2 Then OFF Outstanding job! Would love a tutorial on how to get a trident. Stay tuned for our next tutorial on Feed Cycles. Also just watched the sump level as the Klir filter advances to see the range. YTgyNmU1ZWZkZTRiNjgwMzgxZTZkNmRhZmEzZGQ0MmMxYTE1MGZhMTgwYTI0 Therefore, a leak detection probe should never be placed on top of carpet. It may not display this or other websites correctly. After running the Fusion ATK setup task, the output connected to the PMUP contains this programming: I don't have a Klir filter, so I don't have direct experience, but I do have an idea. Great work! Earn 13,485 Reward Points, Earn 3,270 Reward Points What we didnt know until we arrived was that she got the date wrong, and we actually booked our vacation during the new moon, not the full moon. But it should NEVER wait over 2 hours to run, so if it does Id like to know. For example: will turn on the output at 10:00 and turn it off at 10:02: . The Apex has built-in schedules for lunar cycles. Here is the programming for my Swabbie output: The first line Fallback OFF instructs the Apex to turn off this output if the Apex ever gets disconnected from the Energy Bar where the Swabbie is plugged in. In the above example using If Time where we need the output to turn on for less than 2 minutes, but If Time cant do that, so the Defer delay was used to prevent the output from turning on until the 1 minute delay elapsed. DOW is particularly useful when combined with the If Time command. Ive heard a couple people say the 1 and 2 labels were mixed up during manufacturing. Earn 555 Reward Points, Earn 224 Reward Points Occasionally this powerhead seizes up, causing my 2-part to precipitate. Apex has 32 profiles named PF01 - PF32. If Output Alert_FW_LO = ON Then ON If Output Maintenance = ON Then OFF Here is how I have my power cords connected: Stay tuned for tomorrow's tutorial on Virtual Outputs. My thinking is to let the Klir activate thus putting the system to a level Id call normal. Buy this Neptune Apex Optical Level Sensor (OS1) online from www.reefsupplies.ca . There is likely not another aquarium controller in this price class that will provide you more features, is easier Its best to just always leave it set to AUTO. It is recommended that a sensor not be placed directly on a bare concrete slab. If FeedD 000 Then OFF, If FeedA 005 Then OFF For my swabbie, I just copied your homework and never looked back! Virtual outputs are imaginary outputs that we can use to create more complex programming than would normally be available given the Apex programming limitations. So far in this series we have focused a lot on programming outputs that turn on or turn off devices plugged into Energy Bars. Set OFF Ive found these values work really well on my Radions to look like moonlight: Click the gear icon above your lights output, Click the Advanced (gear icon) at the top right. You can test the probes by placing thethe leak detection probe on a wet paper towel. Lets say you want to run a circulation pump once per day for an hour every day except on Saturday when you are doing maintenance: Remember from my introduction section that the last line of programming that evaluates True will dictate what the output does. Plug the new 12V power adapter into a regular wall power outlet and connect it to the Apex auxiliary power port. This is what the PNWMAS is all about. Comments and suggestions are encouraged, but please keep them positive and constructive. Neptune A3 Apex Jr System The A3 Apex Jr. is the first monitoring only solution that monitors exactly what you need; and, when ready, opens the door to control for all aquarists. Lowered the When command timer from five (5) minutes down to three (3) minutes. But if you do make a shot that hits the rim but doesnt go in, the shot clock is reset and you have another 24 seconds to try again. Thank you for taking the time to make this sensible and logical. If you noticed in my Radion screenshot above, I have additional profiles listed in the Advanced coding. If Output Alert_FUG_Hi = ON Then ON APEX PRO Solid Surface Leak Sensor When it comes to water on the floor, time is critical. The Min Time command is similar to Defer, but with a distinct difference: In other words, the output must remain in the specified state for the specified period of time, regardless of the conditions listed in the output programming. The Apex evaluates each Output programming once per second, so when a condition changes it should react to that change within 2 seconds. Defer 120:00 Then ON, Set OFF Once the float switch first reports Open, the Defer countdown timer begins. I refer to them constantly to understand Apex logic. Hello and welcome to my new quest, Alchemical Blade Prequel Quest! $29.99 . Just got my Apex and was setting it up. You really need to push them hard until they "click" into place. 3. Click the gear icon above the new output to configure it. In Fusion, click the down arrow next to your username at the upper right, then click Settings, To add a recipient, click the plus sign icon at the upper right. While the LD-2 utilizes conductive strips to detect fluid leaks on surfaces around your aquarium, the LD-3 takes advantage of optical sensor technology instead. Click the desired input to select it, then edit the Name field. I will order a sensor since I can always use an extra if this doesnt work. For the best experience on our site, be sure to turn on Javascript in your browser. OWJlNTUwNzgwNmUxMDkyOTRmMzMzOWEzZTliMDVkYTBhZjJlMzc0ZmUyZjM1 Question: Can you set the value for defer to "zero" for testing purposes or do you need to have a minimum value (one second) or delete the line altogether? This is effectively saying if the moon is up, AND the time is between 9pm to 7am, then turn ON. Alberto Soler Cambra Data Scientist. Defer statements can be placed anywhere in the list of programming lines because they apply to the output itself and are not part of what evaluates as True or False. With a wire length of 5 meters (16.3ft) this sensor is a must have for placement inside and outside of your sump. Let me know if this is a possibility, and if so I'd be happy to assist with the programming. While the LD-2 utilizes conductive strips to detect fluid leaks on surfaces around your aquarium, the LD-3 takes advantage of optical sensor technology instead. If FeedB 005 Then OFF Switch the Control Type to Advanced. Looking forward to more in this series. That means moving the Apex to the temporary tank that will be in the garage,. cleaning up the existing tank while the living room is being worked on and then moving it all a second time back to the original location. My favorite example is a warning if my ATO hasnt run recently. Heaters, lights,and anything with powerful motors (like return pumps or skimmers) will drain the battery quickly, so they should be turned off. If ATK_HI CLOSED Then OFF That frequency will be determined later. First time poster for a problem so forgive me if this is the wrong place. ZjUxNWU5MTdjZTg2YjJjOTU2NzIzMmZhM2EzN2Y4MjI0NzU0M2IwYTViMzVk This is achieved by using the delay timer: This forces the skimmer to wait an additional 5 minutes after the Feed Cycle has completed. If Output vSMP_Lo = ON Then ON it is designed to be placed on solid flat surfaces. If you have an account, sign in now to post with your account. By that time, the return pump has brought the sump water level back down to normal so the skimmer doesnt overflow. Heres how I use mine: This is accomplished by adding the following line to each output youd like off during the Feed Cycle: For example, the powerheads are turned off with this code: For the skimmer, I need it to wait for the sump water level to return to normal after the return pump has been off. We Also Recommend I/O Breakout Box $4495 0.25" Flow Sensor $2095 0.5" Flow Sensor $3195 1" Flow Sensor $6295 Residual moisture in concrete may cause false alarms. Advertise today. It would be better to change the sequence to: Now when you receive the alarm about the Temp > 99, youll run out of the theater and head right home. If Output Alert_Power = ON Then ON Onteniente, Valencian Community, Spain 6 connections Its one of the most important reasons for using a controller. The FMM (Fluid Monitoring Module) is a multi-purpose device that, with the help of various accessories, enables your Apex to do: With the various flow monitoring sensors you can monitor the flow inside the pipes of your return pump, emergency drains, reactor pumps, RODI feed, and much more. Neptune Apex Programming Tutorials Part 8 and Conclusion: Lunar Schedule and Lighting Profiles, 000:00 = zero minutes from midnight until the first run, 358:00 = 5 hours & 58 minutes to delay until the next run, Defer - will delay an outlet from changing its state for a specified period of time, Min Time - will ensure an outlet stays in its current state for a minimum period of time. If Float1 Open Then ON If FW_LOW OPEN Then OFF OUR ORIGINAL AQUARIUM CONTROLLER The Apex Classic is the original Apex introduced in 2009. OGY5YTRiYzU4MjJlOWFiMTFkODA4OGMwMWEyYzlhYmU1OGEwMzg1YmM2NWM3 There are severalsources of alarms: Note: If you have an older Apex with the Display module, it provides audible alarms through a small speaker. Cant believe these articles dont have more likes. In our final tutorial tomorrow Ill cover Lunar Schedules and Lighting Profiles. Your article clarified the whole thing. We are just lucky to get to host it and have first shot at reading it. In my Email_Alarm output, I added this line: This triggers the actual email and text message. Place or leave the ACC port tiles (LinkA_#_1) in the unused tile area as well. Probes may have names up to 6 characters long, and may include upper- and lower-case letters, numbers, dash (-) or underscore (_). FMK Flow Monitoring Kit - Neptune Systems, FMM Fluid Monitoring Module - Neptune Systems, OS-1 Optical Level Sensor V2 - Neptune Systems, OS-1-M Optical Level Sensor V2 With Mount - Neptune Systems, ATK V2 Auto Top Off Kit - Neptune Systems, Small CO2 Scrubber (1.1lb Capacity) - IceCap, Medium CO2 Scrubber (2.2lb Capacity) - IceCap, DOS & DDR Dosing System Package - Neptune Systems, A3 Apex Pro Controller System with Extra Energy Bar 832 - Neptune Systems, A3 Apex Controller System with Extra Energy Bar 832 - Neptune Systems, Trident & A3 Apex Pro Controller System Bundle - Neptune Systems, Trident & A3 Apex Controller System Bundle - Neptune Systems, A3 Apex Controller System - Neptune Systems, LD-3 Optical Multi-Surface Leak Sensor - Neptune Systems, MOS Magnetic Optical Sensor - Neptune Systems, A3 Apex Jr Controller System - Neptune Systems, A3 Apex Pro Controller System - Neptune Systems, A6 DC 200 Protein Skimmer - Adaptive Reef, A8 DC 300 Protein Skimmer - Adaptive Reef. Providing a master On/Off switch to easily turn off a number of devices with a single click. Earn 10,830 Reward Points. If they are not divisible into 1440, then each day will be slightly different, and youd have to do some interesting math to figure out when it would turn on on any given day. The item may have some signs of cosmetic wear, but is . Videos Hide Videos 6325 Sandburg Road, Suite 400 Golden Valley, MN 55427. Doing that now and I'm sure there will be issues given Neptune's sparse instructions. Defer 005:00 Then ON, If Moon [+/-] [DELAY] / [+/-] [DELAY] Then [ON/OFF/PROFILE], If Moon 000/000 Then ON - Turn on at moonrise, and off at moonset Click on an EnergyBar outlet you would like to have turn OFF when a leak probe detects water. An Apex system consists of Modules, Inputs, Outputs, and Profiles: All programming is applied exclusively to Outputs. Free . The logic here is a great example; a statement seemingly turns the output on, but other commands placed anywhere randomly in the code delay or modify that command? would be a good outputs to have turn OFF if a leak is detected by the probe(s). Want to grow your business and reach a wider audience? Had a standalone ATK and was about to shelf it since it alarmed ALL the time. Si sigue navegando, aceptas su instalacin y uso. Tomorrow Ill go over Alarms in more detail. This photo is from the Reef2Reef archives courtesy of, https://www.neptunesystems.com/getstarted/atk-help/, Product Launch: StinkSink Skimmer Odor Filter. SuncrestReef, June 1, 2019 in Equipment. Neptune Neptune Systems Liquid Level Sensor - 35 Inch $141.70 5 in stock Sold out Neptune Neptune Systems Trident Reagent Kit - 6 month $141.70 Out of stock Neptune Neptune Apex Flow Sensor - 2 (FS-200) It would then repeat the 7 minute off, 2 minute on cycle. My problem that Im unsure of is how to put that into Apex code. If during that 2 hour timer the sump is refilled and ATK_LO changes to CLOSED, then the Defer timer is reset. Heres an example where I use a virtual output to determine if my Radion lights should simulate moon lighting, but only if the moon is visible, and only if my normal lighting schedule is off: The Apexs built in lunar schedule knows when the moon is above the horizon. When my 2-part dosing containers are low, the optical sensors inside will report OPEN. Instead, use a folded up paper towel or a thick piece of cloth between the probe and the concrete. I tend to place Defer and When commands at the end for ease of reading and troubleshooting. JavaScript is disabled. She researched it and planned our trip to coincide with the full moon in November 2012. MjIxNDg4NGFjM2RhOGIxNjgyYTI5OGY0NzZhODU3ZDczN2ViODQ1NWNiOTll If LkSump CLOSED Then OFF I guess we would use the half cycle time as average even though its probably not linear. You really need to push them hard until they click into place. Equipment Discussion for Saltwater and Reef Aquari, This photo is from the Reef2Reef archives courtesy of, Neptune Apex Programming Tutorials, Part 3: Automatic Top-Off Kit (ATK), https://www.neptunesystems.com/getstarted/atk-help/, Wisconsin - Florida delayed due 2 hurricane damage, https://www.reef2reef.com/ams/neptune-apex-programming-tutorials-part-4-power-monitoring.698/, Neptune ATK V2 Auto Top Off with Leak Detect probe, Using ATK with PMUP during day, and DOS over night for KALK. Over the past year Ive become much more comfortable and proficient in Apex programming, and I've become a frequent contributor on the Neptune Community Forums and Neptunes Apex Community Facebook group where I do my best to help answer questions posted by other confused users. The program is above the dashed line, and the last line to evaluate as True dictates how to set the output state. If you manually set an output to ON or OFF, it will remain in that state until you manually change it. THE ULTIMATE MULTIPURPOSE FLUID-MONITORING DEVICE! Heres my current EmailAlm output programming: Again, I want to emphasize the importance of placing the least important alarm conditions at the top of the list, and the most critical towards the bottom. Once the new output has been created, Fusion will indicate that a new tile is available. Frustrating and a LOT of email/text warnings. Neptune Systems is doing physical inventory between 01/11/23 through 1/16/23. Notice in this example we have changed the ending result to OFF instead of ON like used in the email program. The next step is to create a lighting profile. MDZmYjI1NWYwZDkxMjVmMThhMDhmMmNjMDZjZjBiODAwOTZlOTE1YWViNTVj Since my timers multiplied by 4 = 1440, my OSC timers trigger the Swabbie at the same times each day: Midnight, 6am, noon, 6pm. I can see the wattage vary in what looks like steps. Picture Information. Once I discovered the official Neptune Community Forums I found several examples of programming that helped me achieve what I wanted to build. Upload or insert images from URL. 101 sold . While Neptunes documentation walks you through the ATK setup, they dont really provide a lot of information about the resulting programming created by the Fusion ATK Setup task. After this period, the ATK_Lo and ATK_Hi would be ignored/off until the next trigger of the filter dump. I will also have the situation where the level in the filter tray hasnt risen enough to trigger the Klir to advance the fleece but holding up a volume of water. ZGExZjNjMDRiZjNlOGMwZWEwYjYyN2Q1NGRhZjQ1YzAyMTMxOWQwMWYzNTA5 How to. Any line of code that evaluates as True will trigger the alarm. The skimmer waits an additional 5 minutes due to its Defer timer, allowing the sump water level to return to normal before turning on. If FeedC 005 Then OFF Ill cover virtual outputs in another tutorial. Si sigue navegando, aceptas su instalacin y uso. This command is used to react to either an optical sensor, leak sensor, or a switch connected to a Breakout Box port. In addition, all alarms are added to the Apex Alarm Log that can be reviewed later: You can have multiple destinations for alarms. If Time 17:00 to 17:02 Then ON You should have already configured your email address and/or cellular phone number in your Fusion Notifications. Please refer to the APEX Fusion Get Started guide if you have not yet set up notifications. Thanks! Make sure the PMUP output tile is set to AUTO on your dashboard. However, with my 30+ year career in IT systems and my love of all things automation, I realized I could leverage my technical background and the Apex to automate most functions on the aquarium. This master On/Off switch is by far the simplest usage for virtual outputs. In the event of a leak or spill in a carpeted area, the top of carpet may remain dry even if the carpet padding and lower part of the carpet are saturated.